400 GPM FLUSHING/FILTRATION/LOR
HEATING/TRANSFER SYSTEM Duplex
Stainless Steel Filter Vessels with 2" common Inlet/Outlet for .5 micron to 100 micron Filter Elements 3-Way Valves for "Either/Or" Operation Suction/Discharge/Air Elimination/Drain/Sampling Valves Ultra High Velocity Pump Unit with 4" Suction and 3"
Discharge 400 GPM System
Flow Rate Skid Mounted
with Drip Pan Base and Drain Valve Forklift
Skid Lifting (All four sides) with Corner Skid Lifting Eyes Combination Fused Disconnect/Size 2 Motor Starter On-Off-Auto Operation with Running Light Direct Reading Electric/Hydraulic System Differential Pressure
Gauge Auto Shutdown at
15 psid in auto mode Visual
Individual Filter Vessel Differential Pressure Gauges (for operation above 15 psid if desired by operator) All Stainless Steel Flow Path from Pump Discharge through
Filtration System into the Permanent Piping System being Flush Stainless Steel Flanged SuctionDischarge Hose Included 400 GL 100% Stainless Steel Flushing Reservoir Included 36 GPM Air Operated Double Diaphragm Priming/Transfer Pump
with hoses included Footvalve
Suction Assembly for Large Reservoirs included Bolts, Nuts, Spare Filter Vessel O-Rings and Pre-cut Non Asbestos Ring Gaskets included All Equipment shipped in dedicated 20' x 8' x 8' Conex (Approximately
12,000# Total Weight) THIS
SYSTEM IS COUPLED TO OUR 64 KW RECIRCULATING RESERVOIR HEATING SYSTEM WHEN REQUESTED BY THE CLIENT.
DUPLEX WATER FILTRATION SYSTEM This is a very versatile Water Filtration System used for
Prefiltration of Particulate Contamination upstream of Critical Process Systems, such as Reverse Osmosis, Demineralizers,
Cooling Water, etc. Micronic retention from 1-200 (nominal) capability. Utilizing Bag Type Filter Elements for maximum contaminant
loading without high differential pressure, this unit can be operated on a continuous basis while changing filter elements.
Isolation of each vessel allows for one vessel to remain in a "stand-by" mode ready to go into operation with a
clean filter element while the dirty element is replaced and placed into reserve. The system can be operated with both
vessels in service as well, doubling the flow rate of the system. A System By-pass circuit is an integral part of the system
that allows the operator to by-pass both vessels for filter element changes in emergency situations. Construction Materials
are Stainless Steel, Polypropylene and PVC for cleanliness and non corrosion. A direct reading Differential Pressure Gauge
allows the operator to monitor the contaminant loading rate for timely filter element changes. The engineered "drip pan"
base is 100% Stainless Steel with a valved Drain and Hilti Type floor mounting brackets. This System is available in flow
rates from 75 GPM to 1000 GPM.
|
This
Full-Flow Manifold Filtration System is capable of processing Lube Oil or Hydraulic Oil at 1/2 Micron Nominal Particle
Retention, Water Removal or Media Treatment for Total Acid Number. It contains Differential Pressure Gages, Isolation Valves,
Air Eliminator Valves and Drain Valves. The system features
the ability of EHC to custom fit an array of Filtration Units for specific applications, such as, but not limited to: - Turbine Generator
Lube Oil Systems
- Boiler Feed Pump Turbines
- Ancillary Systems of all types
- Fluid Remediation of all types
This Multi-Element Filter Skid is utilized
on Ancillary Systems for Full-Flow Filtration at Ultra High Velocity Flow and provides 1/2 micron nominal particle retention.
This style Filtration System is available from 500 to 6,000 GPM. Each System is equipped with Differential Pressure Gages,
Air Eliminator/Blow Down Valve and Drain Valve, all mounted on a Forklift Base for easy movement within your plant.

This Filtration System is designed for
protecting the Hydrogen Seals on Generators from contamination. EHC Field Services, Inc. manufactures and installs these systems.
Contact EHC for details.
EHC HAS DEVELOPED A PROPRIETARY
CONTROL SYSTEM FOR ITS' LUBE OIL RESERVOIR HEATING UNITS THAT ENABLE THE USE OF SELECTED HEATER ELEMENTS. THIS SYSTEM IS VERY
VALUABLE FOR RAPID THERMAL SHOCK PROCEDURES AS WELL AS MAINTAINING A PREDETERMINED TARGET TEMPERATURE FOR THE RESERVOIR. THIS
HEATING SYSTEM IS ALSO VALUABLE FOR MAINTAINING RESERVOIR TEMPERATURE IN COLD CLIMATES FOR PEAKING AND STAND-BY UNITS THAT
ARE STARTED ON SHORT NOTICE. ASK ABOUT EHC'S EQUIPMENT SALES PROGRAM.
|

This
100% Stainless Steel, Skid Mounted Reservoir is purpose designed to enable the Ultra High Velocity Lube and Control Oil
Flushing of the following Ancilliary and Non-Adequate Fluid Capacity Systems: - STG & GTG EHC SYSTEMS
- STG &
GTG SEAL OIL SYSTEMS
- STG LUBE OIL COOLER SYSTEMS
- STG BOILER FEED PUMP TURBINE LUBE OIL SYSTEMS
- STG & GTG LUBE OIL STORAGE AND TRANSFER SYSTEMS
- GTG
AIR COOLED LUBE OIL COOLER SYSTEMS
- FUEL OIL SYSTEMS
When utilized with EHC Ultra High Velocity Flushing Skids, this System is second to none for efficiency.
|
|

These Filter Units remove contaminants that have been loosened and suspended by the High
Velocity Flow of the Lube Oil. The Units have 2" Inlet/Outlets and utilize a Size 1 Filter Bag. The Flush Operator
can visually monitor the loading of the Bags to determine the affect of the Flush Procedure.There are isolation valves on
the inlet and outlet as well as air elimination and drain valves.The Units are interconnected to the Flush System by SS
Flex Hose. Oil Samples are taken at the Sample Valve on each Vessel. Drip Pans are furnished as part of the Filtration
Configuration. Each Unit is mounted on a Secure Base.
|
EHC Heater Units are designed for Heating the Lube Oil Reservoirs
to the specified Temperature during High Velocity Lube Oil Flushing Procedures. Reserviors from 500 to 20,000 gallons
are processed with a single Unit.

Above and below are pictures of our E30X2718C
Portable Filtration System. This Unit is very valuable for the following tasks: - Reclamation of Lube and Hydraulic Fluids contained in Reservoirs while the system is
in operation or shutdown
- Filtered Transfer
of Fluid from storage tanks or delivery vehicles and drums into operating Reservoirs
- Versatile use of various filter media and micron retentions (Particulate, Water Absorbent,
Acid Treatment)
- 30 GPM Flow Rate
- Positive Displacement Pump
- Differential Pressure Gages (Inlet/Outlet)
- 1-1/2" Stainless Steel Suction and Discharge Hoses with Cam-lok Connectors
- Designed for single person movement and operation

|
|
|

EHC Heater Units have evolved over the past
35 years to an extremely efficient machine that provides controlled heat to Lube Oil Reservoirs of 500 to 20,000 Gallon Capacity.
This Unit has the versatility to provide 16 KW, 32 KW, 48 KW or 64 KW heating capacity from one skid, thermostatically
controlled with redundant "Fail Safe" devices. The electricals are 480V, 3 Phase, 60 Cycle and 100 Amps at
full load.
|
|
|
|
|